• call (727) 807-9516
  • query_builder Weekdays : 07:30AM to 06:00PM and Saturday : 08:00AM to 3:00PM Sunday: By Appointment Only

Stauf CTS-837 Ultra Premium Clear Thin Spread VCT Adhesive - 4 Gal.

$49.50


Report a cheaper price seen elsewhere

We're so confident in our low prices, we offer a Beat-a-Price Guarantee:
We'll beat our competitors' Out the Door price on any identical product.
(Proof of Advertised Price Required)!

  • Shipping Weight: 40lbs
  • Units in Stock : 4
  • Manufactured by: Stauf Adhesives
  • Dimensions: 12in x 12in x 12in
  • Store Code: STACTS8374G48
  • Model: CTS-837-4G
  • Availability :In Stock
  • SHIPS DIRECT FROM: Our Store - Usually ships within 1-3 business days
  • Qty :
    remove add
    Description

    CTS-837 has been formulated to ensure superior adhesive performance under the very
    demanding conditions commonly found in today's fast paced construction and raises the bar for the
    performance of clear thin spread adhesives. This acrylic enhanced formula means that contractors may install vinyl composition (VCT) and asphalt tile over concrete subfloors with elevated moisture emissions and in situ relative humidity levels. The CRI Green-label Plus Adhesive Certification Program has certified CTS-837 as a low VOC adhesive.
    CTS-837 is a ultra premium, professional adhesive that dries quickly and has a long lasting grab
    for the installation of vinyl composition tile (VCT), asphalt tile, and AAT approved carpet cushions
    (urethanes, synthetic fiber, rubber sponge). This acrylic enhanced adhesive dries to a transparent
    film allowing lay-out lines to remain visible. CTS-837 is installer friendly and solvent free.
    CTS-837 spreads easily, has an extended working time, is outstandingly water resistant, and
    nonflammable. Like all of our adhesives, this adhesive is protected by the CleanGuard® two-stage
    antimicrobial. CleanGuard® is a specifically formulated broad-spectrum, anti-microbial agent that
    protects our adhesives and sealers from microorganisms, such as mold or mildew, in both the wet and dry state.

    • Special features

    • High performance formula for installing vinyl composition tile, VCT
    • Fast tack and high shear strength to prevent tile slippage
    • 24 hour working time
    • Superior moisture resistance
    • Excellent final bond
    • Can be used over cutback adhesive residue
    • Chalk lines can be seen through adhesive

     

    Pre-Installation Checklist
    A successful installation requires proper preparation of the sub floor. Read and understand all applicable guidelines and technical data sheets before installation. Follow industry standards and flooring manufacturer's recommendations for sub floor moisture content, design, layout and application of flooring materials. Backing of all flooring material must be solid and sound and free of any anti-adherents. All slab constructions must meet the specific requirements of the floor covering to be installed.
    Sub Floor Examination
    Prior to installation, the sub floor must be checked according to applicable installation guidelines. It must be solid and sound, flat, permanently dry, clean, free of chaps, indentations and anti-adherents, as well as resistant to pressure and tension. Moisture content of all floors must be measured before installation.
    Moisture content in concrete sub floors must be below 8#/24hrs/1,000 sq. ft. using the Calcium Chloride Test or less than 95% RH using the in-situ test per ASTM F1869 and F2170.
    Sub Floor Preparation
    Depending on type and condition of sub floor, a mechanical treatment (e.g. mechanical brushing, grinding or sanding) may be required. Intensity of such work must be determined at the site by the installer. Dust, paint, residual adhesives or other surface contaminants must be removed by suitable means. Cleaning the surface with an industrial vacuum cleaner is recommended. Cracks and gaps must be filled with concrete crack filler unless they are expansion joints. Level when necessary to 3/16 inches within 10 feet. Heated sub floors, gypcrete, wooden sub floors, levelers, patches and light weight concrete must be primed. Fast curing cementitious leveling or patching compounds might reduce the flash and work time of water based products due to absorption.
    Installation Procedure
    Spread the adhesive with the appropriate notched trowel. Avoid excessive adhesive thickness by passing the trowel evenly through the adhesive at a 45 degree angle. Observe the appropriate flash time (if applicable). Lay the flooring into the adhesive, correctly position it and press down firmly. Be sure to check the back of the flooring to make certain good adhesive transfer from sub floor to flooring is achieved. Roll flooring approx. 15-30 min after installation with a 75-100# roller if recommended by the flooring manufacturer. Push down raised edges approx. 30-60 min after installation.
    Storage
    Store and transport protected from freezing. Recommended minimum temperatures are 35 °F for transport and 40 °F for storage. Do not stir product if frozen, allow to thaw completely.
    Limitations
    When using other than STAUF products in conjunction with STAUF primers, sealers, leveling compounds, or adhesives, STAUF denies any and all responsibility for any ensuing problems and/or damages without prior written authorization from STAUF.
    In case of accident, injury, spill or exposure, see SDS sheet for information. Consult technical data sheet at www.staufusa.com for updated information.
    This adhesive will maintain its integrity and performance even when higher levels of moisture are present. While adhesive can withstand up to 8#/24 hrs/1,000 SF (Calcium Chloride Test) and 95% RH (in-situ probe) of moisture, it does not qualify as a moisture inhibitor. Please see below for recommended sealers if a moisture barrier is required. Not suitable for areas with excessive topical moisture (i.e. melting snow, repeated flooding, pressure washing) or extreme horizontal shear forces; use R-Series adhesives under these circumstances.
    The foregoing representations are based on the results of our most current product and material testing within a controlled environment and are of a non-obligatory advisory nature only. As such, they do not constitute an express or implied warranty of any kind including the Warranty of Merchantability and/or Fitness for a Particular Purpose. Because we have no control over the actual quality of workmanship, materials used and worksite conditions, STAUF USA, LLC. will in no event be liable for any incidental and/or consequential damages. herefore, we strongly recommend that prior on-site testing be conducted to refer to and study the suitability of the product for the intended purpose. With the release of this technical information sheet all its prior versions become invalid. For warranty and warranty disclaimer information please see our Limited Lifetime Warranty @ www.staufusa.com
    General Features
    • LEED qualified
    • dries in less than 2 hours
    • contains no VOC (calc. per CA Rule 1168)
    • nonflammable
    • dispersion base cleans with water
    • certified "green", CRI GLP
    Installation Features
    • grabs quicker, less slippage
    • very low odor
    • cleans with warm water and soap
    • high spread rate
    • long open time
    • spreads easily
    • dries quickly
    • higher temp will shorten drying time
    Long Term Features
    • resistant against aging
    • remains elastic
    Approved Flooring
    • VCT (Vinyl Composition Tiles)
    Approved Sub Floors
    • Concrete Slabs
    • OSB (underlayment grade)
    • Plywood (underlayment grade)
    • Cured Leveling Compounds
    • Radiant Heated Sub Floors
    Flash Time (dry lay)
    • 30 - 60 min
    Open Time (dry lay)
    • up to 24 hrs
    Approved Primers
    • Primer is normally not required
    • STAUF AQP-200 Eco-Prime
    Approved Sealers
    • STAUF ACS-210 True-Seal
    Approved Leveling Compounds
    • STAUF SLC-540 Self Leveling Compound
    • STAUF QFF-560 Quick Feather Float
    • STAUF RLC-580 Fiber Level
    Approved Trowels and Spread Rate
    • VCT, asphalt tile over porous-#9 (1/32"x1/16"x1/32" U notch): up to 250 SF/gal.
    • VCT, asphalt tile over non-porous-#13 (1/32"x1/32"x1/32" └┘ notch): up to 350 SF/gal.
    • Carpet cushion-#8 (1/16"x1/16"x1/16" └┘ notch): up to 150 SF/gal.
    Cure Time until Normal Traffic
    • approx. 24 hours
    Clean-Up
    • Use soap and water
    Temperature Range during Installation
    • 50�-90�F
    Relative Humidity Range during Installation
    • 30% - 80%
    Packaging Size
    • 4 gal. Plastic Pail
    • 48 per pallet
    • Case of 4x1 gal Plastic Pails
    • 42 per pallet
    Color
    • Cream
    pH value of concrete
    • must be between 7 and 9
    Transportation
    • above 35�F (do not stir if frozen, allow to thaw completely)
    Storage
    • above 40 �F, protect from freezing
    Shelf Life
    • 12 Months in original, unopened container

    More Information: 
    Reviews (0)
    Cart